Robotic Hand
orcahand v2.1 Touch - Dynamixel - Right hand
By ORCA
A 17-DoF open-source robotic hand with PaXini fingertip tactile sensing: five Hall-effect sensor modules and 363 taxels provide three-axis force measurements for contact-rich manipulation research. The tactile sensing module is proprietary. Selected configuration: orcahand v2.1 Touch; Dynamixel motor platform; right hand. One selected hand per unit. Manufacturer images show the orcahand v2.1 Touch family and may depict a different handedness or motor platform. The supplied hand and motor platform follow the selected configuration and written quote.
Pricing on request
Quote-only. Confirm handedness, motor option, availability and delivery in your written quote.
Your Configuration
Quote required
One or more selected items need a quote. Your request will include every selected product and quantity.
Quote required for:Pricing on request
All sales are final across all brands. No customer-requested cancellations, returns, exchanges, or refunds, except where required by law or expressly agreed in writing. Manufacturer warranty claims go to the manufacturer; Knoxlabs can help with order details and support contacts.
- Selected configuration: orcahand v2.1 Touch; Dynamixel motor platform; right hand. One selected hand per unit.
- Manufacturer images show the orcahand v2.1 Touch family and may depict a different handedness or motor platform. The supplied hand and motor platform follow the selected configuration and written quote.
- The optional Max Kit is separately quoted and is not included by default. Spare consumables do not add a second hand.
- Quote-only: specify handedness, motor option and quantity.
- Availability, mounting requirements and delivery are confirmed in your quote.
Product details
Selected configuration
Selected configuration: orcahand v2.1 Touch; Dynamixel motor platform; right hand. One selected hand per unit.
Manufacturer images show the orcahand v2.1 Touch family and may depict a different handedness or motor platform. The supplied hand and motor platform follow the selected configuration and written quote.
The optional Max Kit is separately quoted and is not included by default. Spare consumables do not add a second hand.
A 17-DoF open-source robotic hand with PaXini fingertip tactile sensing: five Hall-effect sensor modules and 363 taxels provide three-axis force measurements for contact-rich manipulation research. The tactile sensing module is proprietary.
Quote-only. Contact Knoxlabs to confirm configuration, availability and pricing.
Technical highlights
- Active degrees of freedom: 17: 16 tendon-driven finger DoF and 1 belt-driven wrist DoF
- Actuators: 17 servos; assisted auto-tensioning
- Power: 12 V, 5 A adapter included; 5.5 × 2.1 mm barrel jack
- Data connection: USB-C (USB 2.0), data only; not powered over USB
- Cooling: Two 12 V fans
- Mounting: Aluminum ISO 9409-1 plate; Ø63 mm flange, Ø50 mm bolt circle, 4 × Ø6.5 mm holes for M6
- Hand and motor choices: Right hand; Dynamixel motor platform
- Overall dimensions (H × W × D): 330 × 93 × 105 mm; base footprint 93 × 96 mm
- Weight: Approximately 1.25 kg
- Rated motion life: 80,000 cycles, then new sensor cables
- Structure and skin: Aluminum spool holders, PLA structure, steel and PTFE tendon guides; silicone palm and finger skin
Fingertip tactile sensing
- Fingertip modules: 5 Hall-effect three-axis force modules
- Taxels: 363 per hand; Fx, Fy and Fz output per taxel
- Force range: Normal Fz 0–25 N; tangential Fxy ±10 N
- Minimum detectable force: 0.1 N
- Spatial resolution: 1 mm
- Measurement accuracy: 1% FS
- Output frequency: 50 Hz
- Sensor warranty: 1 year on the touch sensors
Control, simulation and teleoperation
The open-source Python control stack includes browser-based setup and calibration, URDF and MJCF models, STEP files, a MuJoCo learning environment, teleoperation and LeRobot dataset recording. The supplier lists webcam input, MANUS gloves and Apple Vision Pro as supported teleoperation inputs. Meta Quest and Rokoko glove support is listed as coming soon.
Python control stack · Setup and calibration · MuJoCo simulation · Teleoperation and robot learning
What's included
12 V, 5 A adapter, USB-C cable, ISO 9409-1 Franka mounting plate, three spare sensor cables, five spare spool systems, parts to rebuild one finger (including 1.5 m tendon, pins and bearings), magnets and screws.
The optional Max Kit adds spare sensor cables for two entire sensor-cable swaps, a hard-shell travel case, 16 extra spool systems and tendon for respooling an entire second hand. Other connector plates are available on request; confirm the robot-arm interface in your quote.
Configuration and ordering
Request a quote for the selected right hand with Dynamixel servos. Both motor options use the same orca_core software. Specify handedness, motor option, quantity, robot-arm mounting requirements and any optional Max Kit in your inquiry. Pricing, availability, delivery and support scope are confirmed in the written quote.
Getting started with ORCA
Mount the hand using the specified A50 flange or a confirmed adapter. Connect separate power and USB-C data to your PC, install orca_core and complete calibration. Follow ORCA’s walkthrough for your first control scripts. Native ROS 2 integration is not provided.
Features
- 17 active DoF—16 tendon-driven finger DoF and a belt-driven wrist.
- Fingertip force sensing—Five Hall-effect modules, 363 taxels per hand and three-axis force output.
- Selected configuration—Dynamixel motor platform; right hand.
Technical Specifications
Product specifications, requirements, and deployment details.
Selected configuration
- Model
- orcahand v2.1 Touch
- Motor platform
- Dynamixel
- Hand
- Right
- Listing SKU
- v2.1-touch-dx-r
Motion, dimensions and interfaces
- Active degrees of freedom
- 17: 16 tendon-driven finger DoF and 1 belt-driven wrist DoF
- Actuators
- 17 servos; assisted auto-tensioning
- Power
- 12 V, 5 A adapter included; 5.5 × 2.1 mm barrel jack
- Data connection
- USB-C (USB 2.0), data only; not powered over USB
- Cooling
- Two 12 V fans
- Mounting
- Aluminum ISO 9409-1 plate; Ø63 mm flange, Ø50 mm bolt circle, 4 × Ø6.5 mm holes for M6
- Hand and motor choices
- Right hand; Dynamixel motor platform
- Overall dimensions (H × W × D)
- 330 × 93 × 105 mm; base footprint 93 × 96 mm
- Weight
- Approximately 1.25 kg
- Rated motion life
- 80,000 cycles, then new sensor cables
- Structure and skin
- Aluminum spool holders, PLA structure, steel and PTFE tendon guides; silicone palm and finger skin
Fingertip tactile sensing
- Fingertip modules
- 5 Hall-effect three-axis force modules
- Taxels
- 363 per hand; Fx, Fy and Fz output per taxel
- Force range
- Normal Fz 0–25 N; tangential Fxy ±10 N
- Minimum detectable force
- 0.1 N
- Spatial resolution
- 1 mm
- Measurement accuracy
- 1% FS
- Output frequency
- 50 Hz
- Sensor warranty
- 1 year on the touch sensors
Deployment Expertise
Product specialists on staff
Device Configuration
Provisioned & ready to use
Enterprise Support
Hardware, software & deployment help
Global Fulfillment
Shipped worldwide
Need help with deployment?
Knoxlabs also handles the deployment.