Skip to content

Robotic Hand

orcahand v2.1 Touch

By ORCA

Selected configuration: Dynamixel / Left. A 17-DoF open-source robotic hand with PaXini fingertip tactile sensing: five Hall-effect sensor modules and 363 taxels provide three-axis force measurements for contact-rich manipulation research. The tactile sensing module is proprietary. One selected hand per unit. Manufacturer images show the orcahand v2.1 Touch family and may depict a different handedness or motor platform. The supplied hand and motor platform follow the selected configuration and written quote. The optional Max Kit is separately quoted and is not included by default. Spare consumables do not add a second hand.

Pricing on request

Quote-only. Confirm handedness, motor option, availability and delivery in your written quote.

Model: Touch
Motor platform: Dynamixel
Hand: Left

Your Configuration

Pricing on request

Main product quantity

All sales are final across all brands. No customer-requested cancellations, returns, exchanges, or refunds, except where required by law or expressly agreed in writing. Manufacturer warranty claims go to the manufacturer; Knoxlabs can help with order details and support contacts.

  • Quote-only: specify handedness, motor option and quantity.
  • Availability, mounting requirements and delivery are confirmed in your quote.

Request a quote

Tell us what you need — hardware, software, and deployment support can be quoted together.

We respond within 24 hours — typically much faster during business hours.

Product details

per item

Product details

Overview

Selected configuration: Dynamixel / Left.

A 17-DoF open-source robotic hand with PaXini fingertip tactile sensing: five Hall-effect sensor modules and 363 taxels provide three-axis force measurements for contact-rich manipulation research. The tactile sensing module is proprietary.

Quote-only. Contact Knoxlabs to confirm configuration, availability and pricing.

Technical highlights
  • Active degrees of freedom: 17: 16 tendon-driven finger DoF and 1 belt-driven wrist DoF
  • Actuators: 17 servos; assisted auto-tensioning
  • Power: 12 V, 5 A adapter included; 5.5 × 2.1 mm barrel jack
  • Data connection: USB-C (USB 2.0), data only; not powered over USB
  • Cooling: Two 12 V fans
  • Mounting: Aluminum ISO 9409-1 plate; Ø63 mm flange, Ø50 mm bolt circle, 4 × Ø6.5 mm holes for M6
  • Hand and motor choices: Left or right; Dynamixel or Feetech
  • Overall dimensions (H × W × D): 330 × 93 × 105 mm; base footprint 93 × 96 mm
  • Weight: Approximately 1.25 kg
  • Rated motion life: 80,000 cycles, then new sensor cables
  • Structure and skin: Aluminum spool holders, PLA structure, steel and PTFE tendon guides; silicone palm and finger skin
Fingertip tactile sensing
  • Fingertip modules: 5 Hall-effect three-axis force modules
  • Taxels: 363 per hand; Fx, Fy and Fz output per taxel
  • Force range: Normal Fz 0–25 N; tangential Fxy ±10 N
  • Minimum detectable force: 0.1 N
  • Spatial resolution: 1 mm
  • Measurement accuracy: 1% FS
  • Output frequency: 50 Hz
  • Sensor warranty: 1 year on the touch sensors
Control, simulation and teleoperation

The open-source Python control stack includes browser-based setup and calibration, URDF and MJCF models, STEP files, a MuJoCo learning environment, teleoperation and LeRobot dataset recording. The supplier lists webcam input, MANUS gloves and Apple Vision Pro as supported teleoperation inputs. Meta Quest and Rokoko glove support is listed as coming soon.

Python control stack · Setup and calibration · MuJoCo simulation · Teleoperation and robot learning

What's included

12 V, 5 A adapter, USB-C cable, ISO 9409-1 Franka mounting plate, three spare sensor cables, five spare spool systems, parts to rebuild one finger (including 1.5 m tendon, pins and bearings), magnets and screws.

The optional Max Kit adds spare sensor cables for two entire sensor-cable swaps, a hard-shell travel case, 16 extra spool systems and tendon for respooling an entire second hand. Other connector plates are available on request; confirm the robot-arm interface in your quote.

Configuration and ordering

Request a quote for a left or right hand with Dynamixel or Feetech servos. Both motor options use the same orca_core software. Specify handedness, motor option, quantity, robot-arm mounting requirements and any optional Max Kit in your inquiry. Pricing, availability, delivery and support scope are confirmed in the written quote.

Resources
Getting started with ORCA

Mount the hand using the specified A50 flange or a confirmed adapter. Connect separate power and USB-C data to your PC, install orca_core and complete calibration. Follow ORCA’s walkthrough for your first control scripts. Native ROS 2 integration is not provided.

ORCA setup and mounting guide · Watch the setup walkthrough

Features

  • 17 active DoF—16 tendon-driven finger DoF and a belt-driven wrist.
  • Fingertip force sensing—Five Hall-effect modules, 363 taxels per hand and three-axis force output.
  • Configuration choices—Left/right hands; Dynamixel or Feetech servos.

Technical Specifications

Product specifications, requirements, and deployment details.

Motion, dimensions and interfaces

Active degrees of freedom
17: 16 tendon-driven finger DoF and 1 belt-driven wrist DoF
Actuators
17 servos; assisted auto-tensioning
Power
12 V, 5 A adapter included; 5.5 × 2.1 mm barrel jack
Data connection
USB-C (USB 2.0), data only; not powered over USB
Cooling
Two 12 V fans
Mounting
Aluminum ISO 9409-1 plate; Ø63 mm flange, Ø50 mm bolt circle, 4 × Ø6.5 mm holes for M6
Hand and motor choices
Left or right; Dynamixel or Feetech
Overall dimensions (H × W × D)
330 × 93 × 105 mm; base footprint 93 × 96 mm
Weight
Approximately 1.25 kg
Rated motion life
80,000 cycles, then new sensor cables
Structure and skin
Aluminum spool holders, PLA structure, steel and PTFE tendon guides; silicone palm and finger skin

Fingertip tactile sensing

Fingertip modules
5 Hall-effect three-axis force modules
Taxels
363 per hand; Fx, Fy and Fz output per taxel
Force range
Normal Fz 0–25 N; tangential Fxy ±10 N
Minimum detectable force
0.1 N
Spatial resolution
1 mm
Measurement accuracy
1% FS
Output frequency
50 Hz
Sensor warranty
1 year on the touch sensors
🛠

Deployment Expertise

Product specialists on staff

⚙

Device Configuration

Provisioned & ready to use

🎧

Enterprise Support

Hardware, software & deployment help

🌐

Global Fulfillment

Shipped worldwide

Need help with deployment?

Knoxlabs also handles the deployment.

Device setup
Integration planning
Asset tagging
Shipping coordination
Training and onboarding
Deployment consulting

FAQ

How do I order?
Request a quote and specify left or right hand, Dynamixel or Feetech motors, quantity, mounting requirements and optional accessories.
Does USB-C power the hand?
No. USB-C carries data only. Use the included 12 V, 5 A adapter.
What is included?
12 V, 5 A adapter, USB-C cable, ISO 9409-1 Franka mounting plate, three spare sensor cables, five spare spool systems, parts to rebuild one finger (including 1.5 m tendon, pins and bearings), magnets and screws.
What is the difference between Base and Touch?
Both have 17 active DoF. Touch adds PaXini fingertip tactile sensing with five modules and 363 taxels per hand.

Knoxlabs team

How can we help?

Tell us what you need and the right specialist will get back to you.

We reply within one business day, Monday to Friday. Often sooner.

How urgent is it?

Urgent means it is blocking an order, a deployment or an event.